Coatings/Textures

Coatings & Textures Offered

NCR K-HB
Industrial strength coating designed for industrial work areas and heavy load, traffic aisles. Hi-solids, hi-gloss finish.

NCR K-SATIN
Industrial strength coating designed for industrial work areas and heavy load, traffic aisles. Hi-solids, semi-gloss finish.

NCR L-STIPPLE
Highly textured, industrial strength coating. Hi-solids, semi-gloss finish.

NCR H-SR
Industrial strength, slip resistant coating. Hi-solids, hi-gloss finish containing slip resistant aggregate.

NCR G-ESD
Industrial strength, conductive coating system. Hi-solids, Low Gloss finish, providing static control and dissipation of static electricity.

NCR G-CR
Industrial strength, NOVALAC coating with superior acid, chemical & solvent resistance. Hi-gloss, hi-solids finish.

NCR G-DECO QUARTZ
Decorative multi-colored, quartz coating system. Available in hi-gloss, hi-build, smooth finish or semi-gloss, slip resistant finish. Designed for decorative, aesthetic areas.

Coating Specifications

USES:

NCR K-HB is an industrial strength, 98% solids, hi-gloss, smooth, epoxy coating. Typical use areas are heavy traffic aisles, industrial work areas and clean rooms, where a durable, easily maintainable surface is required.

PRODUCT DESCRIPTION:

NCR K-HB is a two component, hi-build, hi-solids industrial epoxy coating system composed of:

               PRIMER:              Two component epoxy primer yielding adhesion to concrete.

               OFR K-HB:           Two component hi-build, epoxy coating applied to yield a smooth, highly reflective, glossy finish.

PHYSICAL PROPERTIES:

% Total Solids                    –   98%
Service Time @77°F         –   8 hours
Gloss 60°F                          –   90+
Coverage                            –   At 10 mils coverage is 150 sq. ft./gallon

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                           NR
Cyclohexane                       NR
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                            L
Methylene Chloride          NR
MIBK                                    NR
Nitric Acid 5%                     NR
Phosphoric Acid                 NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  R

Nationwide Concrete Restoration Epoxy K-HB Coatings are available in twenty standard colors.

 

STATIC COEFFICIENT OF FRICTION
Test Method: ASTM D-2047 James Machine

Sample IDDry Wet1 OilyOily Wet
Standard Neolite0.910.90N/AN/A
Commercial Neolite0.960.75N/AN/A
Leather0.88N/AN/AN/A

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 98% solids epoxy shall be applied at the amount of 150 square feet per gallon.

3) Coating
A hi-build, hi-solids pigmented epoxy coating is applied using a roller or squeegee, backrolling the surface layer to provide a uniform density. The top coat will facilitate easier cleaning and maintenance of entire system.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR K-SATIN is an industrial strength, 98% solids, semi-gloss, epoxy coating. Typical use areas are heavy traffic aisles, work areas, assembly areas where some amount of texture is desired. The textured surface remains cleanable and easily maintained.

PRODUCT DESCRIPTION:

NCR K-SATIN is a two component, hi-solids industrial epoxy coating system composed of:

               PRIMER:              Two component epoxy primer yielding adhesion to concrete.

               NCR K-SATIN:     Two component, slightly textured, epoxy coating. Applied to yield a semi-gloss, orange peel like, textured finish.

PHYSICAL PROPERTIES:

% Total Solids                    –   98%
Service Time @77°F          –   8 hours
Coverage                             –   At 6-8 mils coverage is 200 sq. ft./gallon

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                           NR
Cyclohexane                       NR
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                            L
Methylene Chloride          NR
MIBK                                   NR
Nitric Acid 5%                    NR
Phosphoric Acid                NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  R

Nationwide Concrete Restoration Epoxy K-SATIN Coatings are available in twenty standard colors.

 

STATIC COEFFICIENT OF FRICTION
Test Method: ASTM D-2047 James Machine

Sample IDDryWet1OilyOily Wet
Standard Neolite0.900.84N/AN/A
Commercial Neolite0.950.68N/AN/A
Leather0.52N/AN/AN/A

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 98% solids epoxy shall be applied at the amount of 200 square feet per gallon.

3) Coating
A hi-build, hi-solids pigmented epoxy coating is applied using a roller or squeegee, backrolling the surface layer to provide a uniform density. The top coat will facilitate easier cleaning and maintenance of entire system.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR K-Stipple is an industrial strength, 98% solids, semi-gloss, highly textured epoxy coating. Typical use areas are heavy traffic aisles and work areas where a high amount of texture is desired.

PRODUCT DESCRIPTION:

NCR K-Stipple is a two component, hi-solids, highly textured industrial epoxy coating system composed of:

               PRIMER:              Two component epoxy primer yielding adhesion to concrete.

               NCR K-STIPPLE:   Two component epoxy coating applied to yield a semi-gloss, highly exaggerated, textured finish.

PHYSICAL PROPERTIES:

% Total Solids                    –   98%
Service Time @77°F          –   8 hours
Coverage                            –   At 25 mils coverage is 80 sq. ft./gallon

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                           NL
Cyclohexane                       NL
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                            L
Methylene Chloride         NR
MIBK                                   NR
Nitric Acid 5%                    NR
Phosphoric Acid 5%          NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  R

Nationwide Concrete Restoration Epoxy K-STIPPLE Coatings are available in twenty standard colors.

 

STATIC COEFFICIENT OF FRICTION
Test Method: ASTM D-2047 James Machine

Sample IDDryWet1OilyOily Wet
Standard Neolite0.900.84N/AN/A
Commercial Neolite0.950.68N/AN/A
Leather 0.52N/AN/AN/A

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 98% solids epoxy shall be applied at the amount of 150 square feet per gallon.

3) Coating
A hi-build, hi-solids pigmented epoxy coating is applied using a roller or squeegee, backrolling the surface layer to provide a uniform density. The top coat will facilitate easier cleaning and maintenance of entire system.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR H-SR is an industrial strength, slip resistant coating. It is a moderate gloss, high-solids epoxy coating with aluminum oxide additives, resulting in a slip resistant finish. Highly oily, greasy manufacturing plants, fork lift ramps and pedestrian walkways are typical use areas.

PRODUCT DESCRIPTION:

NCR H-SR is a two component, hi-solids industrial epoxy coating composed of:

               PRIMER:              Two component epoxy primer yielding adhesion to concrete.

               NCR H-SR:           Two component epoxy coating with selected grades of aluminum oxide broadcasted into the coating, in coverages specific to users slip resistant requirements.

PHYSICAL PROPERTIES:

% Total Solids                    –   98%
Service Time @77°F          –   8 hours
Coverage                            –   At 10 mils coverage is 160 sq. ft./gallon

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                           NR
Cyclohexane                       NR
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                             L
Methylene Chloride          NR
MIBK                                   NR
Nitric Acid 5%                    NR
Phosphoric Acid 5%          NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  R

Nationwide Concrete Restoration Epoxy H-SR Coatings are available in twenty standard colors.


STATIC COEFFICIENT OF FRICTION

Test Method: ASTM D2047 James Machine |#54 Aluminum Oxide on NCR K-HB

Sample IDDryWet
(25 mls H2O)
OilyOily/ Wet
(25 mls H2O)
Lab Standard Neolite0.95 0.910.551 0.441
0.4420.432
Lab Commercial Neolite0.810.720.4210.371
0.4420.382
Lab Leather0.72N/AN/AN/A

 

STATIC COEFFICIENT OF FRICTION
Test Method: ASTM D2047 James Machine |#36 Aluminum Oxide on NCR K-HB

Sample IDDryWet
(25 mls H2O)
OilyOily/ Wet
(25 mls H2O)
Lab Standard Neolite0.960.950.7610.661
0.6420.602
Lab Commercial Neolite0.950.890.8110.581
0.7520.562
Lab Leather0.96N/AN/AN/A

 

STATIC COEFFICIENT OF FRICTION
Test Method: ASTM D2047 James Machine |#36 Aluminum Oxide on NCR K-HB

Sample IDDryWet
(25 mls H2O)
OilyOily/ Wet
(25 mls H2O)
Lab Standard Neolite0.960.960.771 0.691
0.7420.702
Lab Commercial Neolite0.950.960.6610.571
0.6620.572
Lab Leather0.96N/AN/AN/A

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 98% solids epoxy shall be applied at the amount of 160-200 square feet per gallon.

3) Coating
A hi-build, pigmented epoxy coating is broadcast with aluminum oxide to reduce slip resistance. Aluminum oxide (sizes #24, #36, #54) coverage options available according to the following table:

Low
Density
Coverage
Moderate
Density
Coverage
High
Density
Coverage
30 sq. ft. approx.25 sq. ft.20 sq. ft.
= 2 lb. oxide= 2 lb. oxide= 2 lb. oxide

Other oxide sizes available upon special request.

Using a medium nap sleeve, backroll the grit-imbedded surface to provide an epoxy coating over the grit and uniform appearance.

PART 3 CLEANING RECOMMENDATIONS

NCR products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR G-ESD is a conductive epoxy coating system designed to meet the Department of Defense specifications of <105 ohms/square. Static dissipating coatings are designed to meet National Fire Protective Code (NFPA-56A) to eliminate fire hazard by bleeding off static electrical charges. This coating cures to a hard finish with excellent compressive, flexural, and tensile strength.

Defense facilities, computer manufacturing, pharmaceutical manufacturing and other facilities requiring a sanitary, static charge control environment are typical users.

PRODUCT DESCRIPTION:

NCR G-ESD is a three component, hi-solids, industrial epoxy coating composed of:

               PRIMER:              Two component epoxy conductive primer.

               OFR H-SR:           Two component conductive epoxy coating applied at 4 mils thickness.

PHYSICAL PROPERTIES:

% Total Solids                    –   98-100%
Pot Life                               –   30-40 minutes
Service Time                      –   8 hours

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                           NR
Cyclohexane                       NR
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                             L
Methylene Chloride          NR
MIBK                                   NR
Nitric Acid 5%                    NR
Phosphoric Acid                NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  L

Nationwide Concrete Restoration Epoxy G-ESD Coatings are available in four standard shades of gray, as well as other selected colors.

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 100% solids conductive epoxy is applied at the amount of 300 square feet per gallon.

3) Coating
A hi-solids pigmented conductive epoxy coating is applied 4 mils thickness. This will achieve a textured finish that facilitates ease of cleaning and maintenance. Resistance range (ohms) variable upon customer requirements.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

Conductive Coatings – Clean as above. DO NOT wax the surface. This will take away the conductivity of your coating.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR G-CR is an acid and chemical resistant, industrial strength, epoxy coating. The Epoxy Novalac top coat provides superior resistance to acid and chemical spillages and corrosive attack.

Ohio Floor Resurfacing’s advanced formulation provides superior defense against inorganic and organic acids, in addition to corrosive chemicals.Epoxy Novalac extends the life expectancy of concrete exposed to harsh acid and chemical spills.

Applications are appropriate for waste water treatment plants, battery acid areas, chemical plants, food and beverage plants.

PRODUCT DESCRIPTION:

G-CR is a two component, hi-build, hi-solids, acid resistant, industrials epoxy coating system composed of:

               PRIMER:              Two component Novalac acid resistant primer yielding adhesion to concrete.

               NCR G-CR:           Two component hi-build, Novalac acid resistant epoxy coating.

PHYSICAL PROPERTIES:

% Total Solids                     –   98%
Service Time @77°F          –  10-12 hours
Gloss 60°                             –   90+
Coverage                             –   At 10 mils coverage is 150 sq. ft./gallon

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   R
Aromatic Hydrocarbons  R
Butanol                               R
Citric Acid                            R-L
Cyclohexane                       R
Ethylene Glycol                  R
Hydrochloric Acid 35%     R
Jet Fuel                                R
Kerosene                             R
Methylene Chloride          NR
MIBK                                    R
Nitric Acid 25%                  R
Petrol                                   R
Phosphoric Acid 25%        R
Potassium Hydroxide       R
Sulfuric Acid 98%              R
Waste Water, Sewage       R-L
Xylene                                  R

Nationwide Concrete Restoration Epoxy G-CR Coatings are available in twenty standard colors.

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 100% solids epoxy shall be applied at the amount of 150 square feet per gallon.

3) Coating
A hi-build, hi-solids, acid and chemical resistant, pigmented, epoxy coating is applied at 12-15 mils thickness per coat; using a roller or squeegee, backrolling the surface layer to provide a uniform density. The top coat will facilitate easier cleaning and maintenance of entire system.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

USES:

NCR G-DECO QUARTZ is an industrial and commercial decorative epoxy coating system. This coating provides a sanitary surface and aesthetically pleasing tweed look. For use in light manufacturing areas, lobbies, restrooms, offices, cafeteria, or health care facilities.

PRODUCT DESCRIPTION:

G-DECO QUARTZ is a three component, hi-build, decorative coating system comprised of:

               PRIMER:                                    Two component epoxy primer yielding adhesion to concrete.

               NCR G-DECO QUARTZ:           Three component, hi-build, epoxy coating with multi-colored, quartz aggregate broadcast as a decorative medium.

               FINISH COAT OPTIONS:       One-three coats may be applied for slip resistant or hi-build finish (NCR K-HB).

PHYSICAL PROPERTIES:

% Total Solids                     –   98%
Service Time @77°F          –   10-12 hours
Gloss 60°                             –   90+
Finish Thickness                 –   1/16″ minimum on average

 

CHEMICAL RESISTANT GUIDE

The following results are based on 21 day immersions.

               R= Resistant
               L=Limited Resistance
               NR=Not Recommended

Ammonia 25%                   L
Aromatic Hydrocarbons  L
Butanol                               NR
Chromic Acid 40%             NR
Citric Acid                            NR
Cyclohexane                       NR
Ethylene Glycol                  NR
Hydrochloric Acid 20%     L
Jet Fuel                                L
Kerosene                            L
Methylene Chloride          NR
MIBK                                    NR
Nitric Acid 5%                     NR
Phosphoric Acid 5%          NR
Potassium Hydroxide       L
Sulfuric Acid 20%               R
Waste Water, Sewage       NR
Xylene                                  NR

Nationwide Concrete Restoration Epoxy G-DECO QUARTZ Coatings and QUARTZ colors are available in sixteen standard colors.

PART 1  GENERAL

1) Qualifications

  1. Contractor skilled and regularly engaging in manufacturing and installation of epoxy polymer flooring systems of similar size and nature for the past five years.

2) Job Provisions

  1. Concrete (standard six-bag mix) shall have a 28-30 day cure. Quick cure additives (High Early) may be used for a 5-10 day cure. Do not use a sealer on new concrete. Concrete shall have a rough, broom finish.
  2. Utilities, air, electric, water, heat 50°-70°F (air), 50°F or greater (concrete) to be furnished by contractor or user.
  3. Dock for unloading of material and equipment and disposal dumpster for non-toxic dust to be provided by contractor or user.

3) Guarantee

  1. With Nationwide Concrete Restoration’s installation, workmanship and adhesion are guaranteed as specified.

 

PART 2 INSTALLATION

1) Surface Preparation
All areas are mechanically steel shot blasted and/or stone ground to remove all dirt, grease, loose and fatigued concrete; opening the pores of concrete to accept primer.

2) Surface Priming
All expansion joints are filled with an epoxy filler, as needed. Before priming, the entire floor and surrounding area is hand swept; then magnetically broomed to remove all shot and debris. A squeegee coat of 100% solids epoxy shall be applied at the amount of 175 square feet per gallon.

3) Coating
A hi-build, hi-solids pigmented coating is applied. While wet, the coating is saturated with multicolor quartz aggregate. When dry, all excess quartz is removed.

4) Finish Coat
One-to-three coats of clear epoxy is applied. One coat yields a very rough slip resistant finish. Three coats provides a hi-build, smooth finish.

PART 3 CLEANING RECOMMENDATIONS

Nationwide Concrete Restoration products are formulated for long wearability and low maintenance. Periodic cleaning is recommended to maintain the aesthetics of the system.

INITIAL – AFTER CURE
Immediately after application, it is important to keep traffic and debris off the surface until the coating is fully cured (8-12 hours @ 77°F, unless otherwise stated by the manufacturer).

MAINTENANCE
Epoxy Coatings – For cleaning: Warm water and a mild standard industrial detergent works well as a solution. For hi-builds, a squeegee or power scrubber (rider or walk behind) is recommended. If you have a slip resistant floor, a soft bristle scrub (push broom or light weight power scrubber) is recommended.

DO NOT – Use solvents, lacquer thinners or alcohols as cleaning solutions. They may discolor and deteriorate the coatings physical and chemical properties.

DO NOT – Leave cleaning solutions or water puddled on the floor, especially on fresh coating (3-7 days), as discoloration may occur.

DO – Follow Detergent Manufacturers Cleaning Instructions.

 

SPECIAL PROCEDURES FOR STATIC CONTROL:

Use as needed if static electricity occurs.
*Floor system MUST cure minimum of 24 hours prior to any of the following:

  1. Use a linen or cotton mop; apply clear, clean water, at ambient temperature; to the floor.
  2. Allow water to remain on floor approximately 6-10 minutes.
  3. Remove water with mop, squeegee or power vacuum.

Caution: Only treat areas where the water can be completely removed after the 6-10 minute time interval. If water is left longer than the 6-10 minute interval, discoloration may occur.

If you have additional questions call Nationwide Concrete Restoration at 1-419-724-9691.

NCR Epoxy Retail Products
Factory Direct for Professional Use

EPOXY PRODUCT KITS packaged for retail use:

  • Same top quality epoxy as used for industrial and commercial installations
  • Numerous quantities/colors to choose from
  • Great for spot repair of potholes or for below grade restoration

FLOORING KITS are known for:

  • High compressive strength
  • Superior impact resistance
  • Seamless, durable surface

EPOXY COATING KITS can by used:

  • Over the epoxy flooring to seal and enhance the flooring overlayment
  • Alone to protect your concrete and provide an esthetic appearance